Fire Protection Solutions for Pipe Corridors

Tunnel Firefighting Solution

Intelligent protection specialists for pipeline corridor safety

Advanced technology for the safety of the pipeline corridor

Jianan Fire is committed to providing customers with a full range of OEM manufacturing services for small fire protection products. While ensuring the quality and reliable performance of the products, we provide customers with more intelligent and automated fire management and improve fire safety through the intelligent fire fighting IOT cloud platform. With its professional technical team and rich industry experience, Jianan Fire is committed to be your most reliable partner for fire protection products manufacturing.

管廊消防解決方案1

Program overview

Underground urban pipeline integrated corridor. That is to say, in the city underground construction of a tunnel space, electricity, communications, gas, heating, water supply and drainage and other engineering pipeline set in one, with a door maintenance port, lifting port and monitoring system, the implementation of unified planning, unified design, unified construction and management, is to ensure that the operation of the city's important infrastructure and the "lifeline".

Comprehensive pipeline corridor fire protection system composition

The fire protection system of the comprehensive pipeline corridor consists of fire alarm system, automatic gas extinguishing system, electrical fire monitoring system, fire door monitoring system, fire water system, and fire blocking and evacuation system.

Products for fire extinguishing applications in pipeline corridors

  • aerosol
  • Ultrafine dry powder
綜合管廊消防系統組成部分

Products for fire extinguishing applications in pipeline corridors

aerosol

According to the closed space and humid environment of the pipe corridor, Jian'an has targeted to develop the hanging S-type aerosol adapted to pipe corridor application and the S-type small aerosol automatic fire extinguishing device specialized for power distribution cabinet and communication cabinet. Its excellent performance and innovative design, non-rich suitable for corridors, tunnels, subways, electric power and other industries, to help customers improve the stability and reliability of the system.

planning regulations

Jian'an (JA) wall-mounted S-type hot aerosol automatic fire extinguishing device installation design according to: "Gas Extinguishing System Design Code" GB503T0-2005

Protected area and release point setup

  • Protective zone should be relatively closed group space, divided by guest volume, with m3 as the unit of calculation, each protective zone volume does not exceed 2000m3 is appropriate.
  • Doors, windows and maintenance structures in the protection area and the permitted strength shall not be less than 1.2KPa, the fire-resistant limit shall not be less than 0.5h, and the fire-resistant limit of the ceiling shall not be less than 0.25h.
  • Ventilation and air-exchange equipment in the protected area should be able to be shut down automatically before the fire extinguishing device is activated, and production operations that affect the effectiveness of fire extinguishing should be stopped.
  • The electrical start-up circuit between more than one fire extinguishing device shall be connected in series.
  • Each fire extinguishing device should be equipped with a start-up feedback function.

JA Calculation of design dosage of generating agent for thermal aerosol automatic fire extinguishing equipment

  • The fire extinguishing design concentration of a hot aerosol prefabricated fire extinguishing system shall not be less than 1.3 times the extinguishing concentration.
  • The fire extinguishing design concentration of wall-mounted thermal aerosols in the pipeline corridor should not be less than dry 150/m3.
?

Operation and Control

Automatic fire extinguishing systems should have three types of automatic control, manual control and emergency start-up control.

The automatic control device should be activated only after receiving two independent fire signals. Manual control devices and manual and automatic conversion devices should be located in the protection zone outside the door of the evacuation exit for easy operation, the installation height of the center point from the ground l.5m.

?

  • When automatic control is used for start-up, there should be a controllable delayed injection of not more than 30S according to the need for safe evacuation of personnel from the protection zone.
  • Fire-fighting power supply should be adopted. The grounding and the working grounding of the individual component equipment units of the hot aerosol automatic fire extinguishing system shall be established separately.

Each part of the protective earthing must be well connected with the earthing system of the building. If the dedicated protective earthing method is used, its grounding resistance should not be greater than 4Ω; if the common earthing method is used, its grounding resistance should not be greater than 4Ω.
Man than 1Ω.

Thermal aerosol automatic fire extinguishing systems should be protected against lightning.

The gas extinguishing controller should pass the GA61 standard test, and other supporting products should also comply with the relevant national regulations.

Calculation formula for the design dosage of fire extinguishing agent

  • The design usage should be calculated by the following formula W=C2* Kv* V

    Where:W--Designed amount of extinguishing agent (kg)
    C2 - Fire extinguishing design concentration (km/m3)
    V - Net passenger volume of the protection zone (m3)
    Kv - guest product correction factor
    V<500m3.kv=1.0
    500m3≤v<1000m3 . kv=1.1
    V≥1000m3.kv=1.2

?

Ultrafine dry powder

According to the closed space and humid environment of the pipe corridor, Jian'an has targeted to develop the non-storage pressure ultrafine dry powder fire extinguishing device and the storage pressure ultrafine dry powder fire extinguishing device for pipe corridor which are adapted to the application of pipe corridor. Its excellent performance and innovative design are suitable for corridors, tunnels, subways, electric power and other industries, helping customers to improve the stability and reliability of the system.

planning regulations

In view of the ultra-fine powder fire extinguishing agent and fire extinguishing system in recent years, widely used, in order to standardize the production of products, the Ministry of Public Security through the publication of the GA578-2005 "ultra-fine dry powder fire extinguishing agent", GA602-2006 "dry powder fire extinguishing device" product industry standards. As China has not yet promulgated the design and application of ultra-fine dry powder fire extinguishing system industry standards and national standards, in order to standardize the design and construction process of ultra-fine dry powder fire extinguishing system, to provide the necessary design, construction, acceptance basis, Shandong Province promulgated DB37/T1317 "ultra-fine dry powder fire extinguishing system design, construction and acceptance of the norms of the local standards (hereinafter referred to as the "norms").

Design and calculation of fully flooded fire extinguishing system without pipe network

Section 3.3 of the Code provides for the design and calculation of ductless fully flooded fire suppression systems.

3.3.1 which stipulates that the design fire extinguishing concentration of ultra-fine dry powder fire extinguishing agent shall not be less than 1.2 times the manufacturer's fire extinguishing efficiency registration data. And the provisions of the pipeless network fire extinguishing system in the arrangement of fire extinguishing devices, should be sprayed to form an effective fire extinguishing powder in the protection zone is uniformly distributed.3.3.1 stipulates that the general practice of advanced standards at home and abroad. Genan registration data non-storage pressure type is 0.14kg/m3, storage pressure type is 0.15kg/m3.

Calculation formula for the design dosage of fire extinguishing agent

m=C*(Wv-Vg)*K1*K2*K3

Where.
m--Designed dosage of ultra-fine dry powder fire extinguishing agent (kg)
C - ultra-fine dry powder fire extinguishing agent design extinguishing degree (kg/m3), according to the "Code" Article 3.3.1 value; K1 configuration place hazard level compensation factor, according to the "Code" Table 1 value
K2 protective zone is not sealed degree compensation factor, according to "norms" table 2 value K3 an ultra-fine dry powder fire extinguishing device spray uneven complementary coefficient, according to "norms" table 3 value Vg-protection area or else burned body and refractory body of the total volume (m3)
Volume of protection zone W (m3)

Jian'an Pipeline Corridor Fire Protection Project Case Introduction

Baotou New Urban District Comprehensive Pipeline Corridor Project (Phase I)
Songyuan Underground Pipe Corridor Project-Cultural Road
Taihu New Town Pipe Corridor Project
Suzhou Yangcheng Road Underground Comprehensive Tube Corridor
Haikou Comprehensive Underground Pipe Corridor Project
Haixiu Road Haikou City Underground Comprehensive Pipeline Corridor Project Changbin Section

More protection for your peace of mind

Transportation protection

Adopting wooden packaging, having pressure gauge set protection cover and external marking and other protections, fully guarantee the safety of product transportation.

Installation Guarantee

Prefabrication is carried out in the production workshop for the installation environment, and there are after-sales technical engineers on-site to guide and solve installation problems.

after-sales service

Professional technical engineering support to solve customer problems, where the production of quality problems, are free maintenance by our company.

delivery capacity

It has a production and service base covering an area of 60 acres, with complete production equipment; and sufficient reserves of raw materials.

Contact Us Now

If you have any questions or need assistance, please fill out the contact form to the right and a Jianan customer representative will contact you as soon as possible.?

Online Message

Please enable JavaScript in your browser to complete this form.
en_USEnglish

聚力純度檢測 共筑安全長城——引領氣體滅火行業邁向責任與質量共同體

國家公安部、消防救援局及市場監管總局聯合發文,將氣體滅火裝備納入重點消防產品監管目錄,進一步明確了行業質量管控的重要性。長期以來,氣體滅火裝置交付驗收存在“重認證證書、檢測報告等書面紙質文件,輕現場快檢設備或機構實際檢測數據”的現象。

從法規層面來看,國家早已對氣體滅火劑的檢驗驗收作出明確規定。目前,市場上既有現場快速檢測藥劑純度的設備,場外也有專業檢測機構可提供技術支持,通過“現場快檢+專業機構復核”的雙重機制,完全能夠確保藥劑質量可追溯、可驗證。

然而在實際操作中,部分銷售、安裝、驗收及維保單位卻偏離了法規要求:驗收時輕視現場快檢數據的真實性,忽視專業機構的檢測結果,有意繞開法規要求,轉而將重心放在紙質文件的形式審查上,僅憑認證證書、檢測報告等材料便完成驗收流程。

這種“重形式、輕實效”的做法,給了中間商可乘之機。他們為牟取暴利,通過調換藥劑、篡改檢測信息等方式弄虛作假;一旦出現質量問題,便將責任推給生產廠家,甚至惡意污蔑、敲詐勒索,讓本專注于氣體滅火產品生產的廠家背負不實“黑鍋”。事實上,藥劑若出現問題,往往與銷售環節、安裝過程的不規范操作、驗收階段的流于形式或維保環節的疏忽管理密切相關,讓假冒偽劣產品有機可乘,理應由相關責任單位承擔,而非讓生產廠家承受不實指責。

江西劍安消防科技股份有限公司作為行業領軍企業及富有社會責任的企業,始終尋求行業高質量發展的突破之道。近期,該公司建立起包含滅火劑純度現場檢測、電子稱重及紅外線壁厚檢測等系列交付現場質量檢測方案,在保障自身企業利益的同時,為行業樹立了榜樣。這一創新舉措通過引入“現場快檢設備”“專業機構復核”“區塊鏈技術”等實現關鍵質量工序信息數據的抓取存證,并結合“項目多方主體現場見證”等檢測方式,顯著提升了產品質量透明度和可溯源能力。通過“數據保真”和“數字化管理”,劍安公司解決了傳統驗收過度依賴紙質文件導致的糾紛問題,為消費者提供了透明的質量信息,減少了假冒偽劣產品泛濫,優化了消費體驗,增強了市場信任,也為行業回歸合規軌道樹立了標桿。

消防安全關乎人民生命財產安全,關乎社會穩定發展,絕非單一主體的責任。在此呼吁行業各方攜手共進:生產企業應堅守質量底線,主動引入先進檢測技術;銷售、安裝及維保單位需嚴守法規準則,杜絕弄虛作假;驗收機構應強化現場實效檢測,摒棄形式主義;監管部門要持續加大監督力度,筑牢合規防線。讓我們以劍安公司的創新實踐為引領,凝聚“共建、共治、共享”的合力,通過技術創新、數據賦能與責任擔當,共同提升氣體滅火裝備質量管控水平,推動行業回歸高質量發展軌道,為構建更堅實的消防安全防線貢獻力量。

96733e2a-18e9-48e5-8c96-a6c8be1bc4af
劍安消防法律聲明
主站蜘蛛池模板: aaaaa国产欧美一区二区 | 欧美xxxxxhd| 最新国产精品自拍| 欧美一区二区三区四区在线观看| 91人人精品| 人人澡超碰碰97碰碰碰| 欧美一区二区综合| 亚洲精品人| 激情久久综合网| 国产精品午夜一区二区| 久久久久久亚洲精品中文字幕| 午夜精品一区二区三区三上悠亚| 91精品视频一区二区| www亚洲精品| 免费a一毛片| 亚洲精品日本无v一区| 国产精品尤物麻豆一区二区三区| 国产精品一二三区免费| 久久99国产视频| 久久影视一区二区| 国产日韩精品一区二区三区| 久久噜噜少妇网站| 国产三级一区二区| 欧洲在线一区| 欧美乱大交xxxxx古装| 久久九精品| 97人人模人人爽视频一区二区 | 精品日韩久久久| 97人人模人人爽人人喊38tv| 狠狠综合久久av一区二区老牛| 欧美二区在线视频| 精品99在线视频| 久久一区二区精品| 国产精品综合久久| 在线国产二区| 亚洲精品日韩色噜噜久久五月| 欧美激情在线观看一区| 欧美一区二三区人人喊爽| 亚洲欧美色图在线| 蜜臀久久99精品久久一区二区| 正在播放国产一区二区| 91午夜在线观看| 91精品国产91热久久久做人人 | 少妇又紧又色又爽又刺激视频网站| 久久久久亚洲| 国产欧美日韩综合精品一| 午夜伦理在线观看| 国产精品乱码一区| 96国产精品视频| 农村妇女精品一区二区| 日韩av在线中文| 黄色av免费| 日韩一级视频在线| 亚洲国产美女精品久久久久∴| 精品国产九九| 国产精彩视频一区二区| 日本三级韩国三级国产三级| 国产欧美日韩va另类在线播放| 日韩精品久久一区二区三区| 日本美女视频一区二区三区| 欧美亚洲国产日韩| 精品久久综合1区2区3区激情| 国产精品乱码久久久久久久| 99久久国产综合精品麻豆| 中文字幕一区三区| 国产一级片一区| 国产午夜精品一区| 91精品久久天干天天天按摩| 欧美精品久| 色妞www精品视频| 欧美日韩一区二区三区不卡| 久久人人爽爽| 国产69精品久久777的优势| 少妇高潮大叫喷水| 日本一级中文字幕久久久久久| 久久久久国产一区二区三区不卡| 亚洲精品一区二区另类图片| 中文字幕日本一区二区| 国产精品久久久区三区天天噜| 久久99久久99精品免观看软件 | 国产91视频一区| 少妇自拍一区|