Fire Protection Solutions for Pipe Corridors

Tunnel Firefighting Solution

Intelligent protection specialists for pipeline corridor safety

Advanced technology for the safety of the pipeline corridor

Jianan Fire is committed to providing customers with a full range of OEM manufacturing services for small fire protection products. While ensuring the quality and reliable performance of the products, we provide customers with more intelligent and automated fire management and improve fire safety through the intelligent fire fighting IOT cloud platform. With its professional technical team and rich industry experience, Jianan Fire is committed to be your most reliable partner for fire protection products manufacturing.

管廊消防解決方案1

Program overview

Underground urban pipeline integrated corridor. That is to say, in the city underground construction of a tunnel space, electricity, communications, gas, heating, water supply and drainage and other engineering pipeline set in one, with a door maintenance port, lifting port and monitoring system, the implementation of unified planning, unified design, unified construction and management, is to ensure that the operation of the city's important infrastructure and the "lifeline".

Comprehensive pipeline corridor fire protection system composition

The fire protection system of the comprehensive pipeline corridor consists of fire alarm system, automatic gas extinguishing system, electrical fire monitoring system, fire door monitoring system, fire water system, and fire blocking and evacuation system.

Products for fire extinguishing applications in pipeline corridors

  • aerosol
  • Ultrafine dry powder
綜合管廊消防系統(tǒng)組成部分

Products for fire extinguishing applications in pipeline corridors

aerosol

According to the closed space and humid environment of the pipe corridor, Jian'an has targeted to develop the hanging S-type aerosol adapted to pipe corridor application and the S-type small aerosol automatic fire extinguishing device specialized for power distribution cabinet and communication cabinet. Its excellent performance and innovative design, non-rich suitable for corridors, tunnels, subways, electric power and other industries, to help customers improve the stability and reliability of the system.

planning regulations

Jian'an (JA) wall-mounted S-type hot aerosol automatic fire extinguishing device installation design according to: "Gas Extinguishing System Design Code" GB503T0-2005

Protected area and release point setup

  • Protective zone should be relatively closed group space, divided by guest volume, with m3 as the unit of calculation, each protective zone volume does not exceed 2000m3 is appropriate.
  • Doors, windows and maintenance structures in the protection area and the permitted strength shall not be less than 1.2KPa, the fire-resistant limit shall not be less than 0.5h, and the fire-resistant limit of the ceiling shall not be less than 0.25h.
  • Ventilation and air-exchange equipment in the protected area should be able to be shut down automatically before the fire extinguishing device is activated, and production operations that affect the effectiveness of fire extinguishing should be stopped.
  • The electrical start-up circuit between more than one fire extinguishing device shall be connected in series.
  • Each fire extinguishing device should be equipped with a start-up feedback function.

JA Calculation of design dosage of generating agent for thermal aerosol automatic fire extinguishing equipment

  • The fire extinguishing design concentration of a hot aerosol prefabricated fire extinguishing system shall not be less than 1.3 times the extinguishing concentration.
  • The fire extinguishing design concentration of wall-mounted thermal aerosols in the pipeline corridor should not be less than dry 150/m3.
?

Operation and Control

Automatic fire extinguishing systems should have three types of automatic control, manual control and emergency start-up control.

The automatic control device should be activated only after receiving two independent fire signals. Manual control devices and manual and automatic conversion devices should be located in the protection zone outside the door of the evacuation exit for easy operation, the installation height of the center point from the ground l.5m.

?

  • When automatic control is used for start-up, there should be a controllable delayed injection of not more than 30S according to the need for safe evacuation of personnel from the protection zone.
  • Fire-fighting power supply should be adopted. The grounding and the working grounding of the individual component equipment units of the hot aerosol automatic fire extinguishing system shall be established separately.

Each part of the protective earthing must be well connected with the earthing system of the building. If the dedicated protective earthing method is used, its grounding resistance should not be greater than 4Ω; if the common earthing method is used, its grounding resistance should not be greater than 4Ω.
Man than 1Ω.

Thermal aerosol automatic fire extinguishing systems should be protected against lightning.

The gas extinguishing controller should pass the GA61 standard test, and other supporting products should also comply with the relevant national regulations.

Calculation formula for the design dosage of fire extinguishing agent

  • The design usage should be calculated by the following formula W=C2* Kv* V

    Where:W--Designed amount of extinguishing agent (kg)
    C2 - Fire extinguishing design concentration (km/m3)
    V - Net passenger volume of the protection zone (m3)
    Kv - guest product correction factor
    V<500m3.kv=1.0
    500m3≤v<1000m3 . kv=1.1
    V≥1000m3.kv=1.2

?

Ultrafine dry powder

According to the closed space and humid environment of the pipe corridor, Jian'an has targeted to develop the non-storage pressure ultrafine dry powder fire extinguishing device and the storage pressure ultrafine dry powder fire extinguishing device for pipe corridor which are adapted to the application of pipe corridor. Its excellent performance and innovative design are suitable for corridors, tunnels, subways, electric power and other industries, helping customers to improve the stability and reliability of the system.

planning regulations

In view of the ultra-fine powder fire extinguishing agent and fire extinguishing system in recent years, widely used, in order to standardize the production of products, the Ministry of Public Security through the publication of the GA578-2005 "ultra-fine dry powder fire extinguishing agent", GA602-2006 "dry powder fire extinguishing device" product industry standards. As China has not yet promulgated the design and application of ultra-fine dry powder fire extinguishing system industry standards and national standards, in order to standardize the design and construction process of ultra-fine dry powder fire extinguishing system, to provide the necessary design, construction, acceptance basis, Shandong Province promulgated DB37/T1317 "ultra-fine dry powder fire extinguishing system design, construction and acceptance of the norms of the local standards (hereinafter referred to as the "norms").

Design and calculation of fully flooded fire extinguishing system without pipe network

Section 3.3 of the Code provides for the design and calculation of ductless fully flooded fire suppression systems.

3.3.1 which stipulates that the design fire extinguishing concentration of ultra-fine dry powder fire extinguishing agent shall not be less than 1.2 times the manufacturer's fire extinguishing efficiency registration data. And the provisions of the pipeless network fire extinguishing system in the arrangement of fire extinguishing devices, should be sprayed to form an effective fire extinguishing powder in the protection zone is uniformly distributed.3.3.1 stipulates that the general practice of advanced standards at home and abroad. Genan registration data non-storage pressure type is 0.14kg/m3, storage pressure type is 0.15kg/m3.

Calculation formula for the design dosage of fire extinguishing agent

m=C*(Wv-Vg)*K1*K2*K3

Where.
m--Designed dosage of ultra-fine dry powder fire extinguishing agent (kg)
C - ultra-fine dry powder fire extinguishing agent design extinguishing degree (kg/m3), according to the "Code" Article 3.3.1 value; K1 configuration place hazard level compensation factor, according to the "Code" Table 1 value
K2 protective zone is not sealed degree compensation factor, according to "norms" table 2 value K3 an ultra-fine dry powder fire extinguishing device spray uneven complementary coefficient, according to "norms" table 3 value Vg-protection area or else burned body and refractory body of the total volume (m3)
Volume of protection zone W (m3)

Jian'an Pipeline Corridor Fire Protection Project Case Introduction

Baotou New Urban District Comprehensive Pipeline Corridor Project (Phase I)
Songyuan Underground Pipe Corridor Project-Cultural Road
Taihu New Town Pipe Corridor Project
Suzhou Yangcheng Road Underground Comprehensive Tube Corridor
Haikou Comprehensive Underground Pipe Corridor Project
Haixiu Road Haikou City Underground Comprehensive Pipeline Corridor Project Changbin Section

More protection for your peace of mind

Transportation protection

Adopting wooden packaging, having pressure gauge set protection cover and external marking and other protections, fully guarantee the safety of product transportation.

Installation Guarantee

Prefabrication is carried out in the production workshop for the installation environment, and there are after-sales technical engineers on-site to guide and solve installation problems.

after-sales service

Professional technical engineering support to solve customer problems, where the production of quality problems, are free maintenance by our company.

delivery capacity

It has a production and service base covering an area of 60 acres, with complete production equipment; and sufficient reserves of raw materials.

Contact Us Now

If you have any questions or need assistance, please fill out the contact form to the right and a Jianan customer representative will contact you as soon as possible.?

Online Message

Please enable JavaScript in your browser to complete this form.
en_USEnglish

聚力純度檢測(cè) 共筑安全長(zhǎng)城——引領(lǐng)氣體滅火行業(yè)邁向責(zé)任與質(zhì)量共同體

國(guó)家公安部、消防救援局及市場(chǎng)監(jiān)管總局聯(lián)合發(fā)文,將氣體滅火裝備納入重點(diǎn)消防產(chǎn)品監(jiān)管目錄,進(jìn)一步明確了行業(yè)質(zhì)量管控的重要性。長(zhǎng)期以來(lái),氣體滅火裝置交付驗(yàn)收存在“重認(rèn)證證書、檢測(cè)報(bào)告等書面紙質(zhì)文件,輕現(xiàn)場(chǎng)快檢設(shè)備或機(jī)構(gòu)實(shí)際檢測(cè)數(shù)據(jù)”的現(xiàn)象。

從法規(guī)層面來(lái)看,國(guó)家早已對(duì)氣體滅火劑的檢驗(yàn)驗(yàn)收作出明確規(guī)定。目前,市場(chǎng)上既有現(xiàn)場(chǎng)快速檢測(cè)藥劑純度的設(shè)備,場(chǎng)外也有專業(yè)檢測(cè)機(jī)構(gòu)可提供技術(shù)支持,通過(guò)“現(xiàn)場(chǎng)快檢+專業(yè)機(jī)構(gòu)復(fù)核”的雙重機(jī)制,完全能夠確保藥劑質(zhì)量可追溯、可驗(yàn)證。

然而在實(shí)際操作中,部分銷售、安裝、驗(yàn)收及維保單位卻偏離了法規(guī)要求:驗(yàn)收時(shí)輕視現(xiàn)場(chǎng)快檢數(shù)據(jù)的真實(shí)性,忽視專業(yè)機(jī)構(gòu)的檢測(cè)結(jié)果,有意繞開法規(guī)要求,轉(zhuǎn)而將重心放在紙質(zhì)文件的形式審查上,僅憑認(rèn)證證書、檢測(cè)報(bào)告等材料便完成驗(yàn)收流程。

這種“重形式、輕實(shí)效”的做法,給了中間商可乘之機(jī)。他們?yōu)槟踩”├ㄟ^(guò)調(diào)換藥劑、篡改檢測(cè)信息等方式弄虛作假;一旦出現(xiàn)質(zhì)量問題,便將責(zé)任推給生產(chǎn)廠家,甚至惡意污蔑、敲詐勒索,讓本專注于氣體滅火產(chǎn)品生產(chǎn)的廠家背負(fù)不實(shí)“黑鍋”。事實(shí)上,藥劑若出現(xiàn)問題,往往與銷售環(huán)節(jié)、安裝過(guò)程的不規(guī)范操作、驗(yàn)收階段的流于形式或維保環(huán)節(jié)的疏忽管理密切相關(guān),讓假冒偽劣產(chǎn)品有機(jī)可乘,理應(yīng)由相關(guān)責(zé)任單位承擔(dān),而非讓生產(chǎn)廠家承受不實(shí)指責(zé)。

江西劍安消防科技股份有限公司作為行業(yè)領(lǐng)軍企業(yè)及富有社會(huì)責(zé)任的企業(yè),始終尋求行業(yè)高質(zhì)量發(fā)展的突破之道。近期,該公司建立起包含滅火劑純度現(xiàn)場(chǎng)檢測(cè)、電子稱重及紅外線壁厚檢測(cè)等系列交付現(xiàn)場(chǎng)質(zhì)量檢測(cè)方案,在保障自身企業(yè)利益的同時(shí),為行業(yè)樹立了榜樣。這一創(chuàng)新舉措通過(guò)引入“現(xiàn)場(chǎng)快檢設(shè)備”“專業(yè)機(jī)構(gòu)復(fù)核”“區(qū)塊鏈技術(shù)”等實(shí)現(xiàn)關(guān)鍵質(zhì)量工序信息數(shù)據(jù)的抓取存證,并結(jié)合“項(xiàng)目多方主體現(xiàn)場(chǎng)見證”等檢測(cè)方式,顯著提升了產(chǎn)品質(zhì)量透明度和可溯源能力。通過(guò)“數(shù)據(jù)保真”和“數(shù)字化管理”,劍安公司解決了傳統(tǒng)驗(yàn)收過(guò)度依賴紙質(zhì)文件導(dǎo)致的糾紛問題,為消費(fèi)者提供了透明的質(zhì)量信息,減少了假冒偽劣產(chǎn)品泛濫,優(yōu)化了消費(fèi)體驗(yàn),增強(qiáng)了市場(chǎng)信任,也為行業(yè)回歸合規(guī)軌道樹立了標(biāo)桿。

消防安全關(guān)乎人民生命財(cái)產(chǎn)安全,關(guān)乎社會(huì)穩(wěn)定發(fā)展,絕非單一主體的責(zé)任。在此呼吁行業(yè)各方攜手共進(jìn):生產(chǎn)企業(yè)應(yīng)堅(jiān)守質(zhì)量底線,主動(dòng)引入先進(jìn)檢測(cè)技術(shù);銷售、安裝及維保單位需嚴(yán)守法規(guī)準(zhǔn)則,杜絕弄虛作假;驗(yàn)收機(jī)構(gòu)應(yīng)強(qiáng)化現(xiàn)場(chǎng)實(shí)效檢測(cè),摒棄形式主義;監(jiān)管部門要持續(xù)加大監(jiān)督力度,筑牢合規(guī)防線。讓我們以劍安公司的創(chuàng)新實(shí)踐為引領(lǐng),凝聚“共建、共治、共享”的合力,通過(guò)技術(shù)創(chuàng)新、數(shù)據(jù)賦能與責(zé)任擔(dān)當(dāng),共同提升氣體滅火裝備質(zhì)量管控水平,推動(dòng)行業(yè)回歸高質(zhì)量發(fā)展軌道,為構(gòu)建更堅(jiān)實(shí)的消防安全防線貢獻(xiàn)力量。

96733e2a-18e9-48e5-8c96-a6c8be1bc4af
劍安消防法律聲明
主站蜘蛛池模板: 亚洲精品卡一| 日本高清不卡二区| 欧美精品一区二区三区四区在线 | 97久久国产精品| 亚洲激情中文字幕| 久久国产激情视频| 年轻bbwbbw高潮| 欧美日韩中文字幕一区| 国产精品1区二区| 精品久久久久久中文字幕大豆网 | 亚洲四区在线| 国产精品视频一区二区三| 中文字幕av一区二区三区高| 国产91热爆ts人妖在线| 麻豆精品久久久| 免费91麻豆精品国产自产在线观看| 免费观看黄色毛片| 麻豆国产一区二区三区| 91精品福利观看| 国产精欧美一区二区三区久久久| 欧美一级久久久| 国产69精品福利视频| 亚洲欧洲日韩av| 国产vsv精品一区二区62| 精品国产91久久久| 99久久精品免费看国产免费粉嫩| 亚洲va久久久噜噜噜久久0| 欧美在线视频三区| 肥大bbwbbwbbw高潮| 97人人模人人爽人人喊0| 色一情一交一乱一区二区三区| 久久久久久亚洲精品| 国产精品天堂网| 欧美乱战大交xxxxx| 久草精品一区| 亚洲少妇中文字幕| 欧美日韩国产一级| 午夜黄色大片| 国产午夜精品一区二区三区欧美| 日本高清二区| 岛国精品一区二区| 欧美一区二区三区久久精品视| 精品久久不卡| 久久二区视频| 91看片app| 狠狠干一区| 91黄色免费看| 一区二区三区四区中文字幕| 国内视频一区二区三区| 狠狠色噜噜狠狠狠狠米奇7777| 国产乱对白刺激视频在线观看| 男女视频一区二区三区| 2023国产精品久久久精品双| 99精品国产一区二区三区不卡| 国产二区三区视频| 在线国产91| 欧美综合在线一区| 91夜夜夜| 午夜理伦影院| 国产精品乱码久久久久久久久| 久久久精品二区| 欧美精品日韩精品| 欧美乱码精品一区二区| xxxxhdvideosex| 国产亚洲精品久久久456| 国产88av| 国产日韩欧美另类| 91社区国产高清| 69久久夜色精品国产7777| 久久久久国产亚洲| 97视频一区| 精品国产九九| 精品久久久久久中文字幕| 97人人模人人爽人人喊小说| 免费看片一区二区三区| 国产一区观看| 久久人做人爽一区二区三区小说| 久久免费精品国产| 秋霞av电影网| 国产午夜一级一片免费播放| 麻豆国产一区二区三区| 人人澡超碰碰97碰碰碰|